33.03 System Underload Detection Level
Range: 20.0 ~ 200.0 % in 0.1 %
Sets the System Underload level. This feature is triggered when the motor current
exceeds this level. 100% level is based off of the value in H05.
33.04 System Overload/Underload Detection Time
Range: 0.0 ~ 60.0 Sec in 0.1 Sec
Initial value : 10.0 sec
Sets the System Overload/Underload Detection time.
33.05 System Overload/Underload Detection safe zone
Range: 0.00 ~ Max frequency (30.01) in 0.01 Hz
Initial value : 0.00Hz
Sets the level at which this feature is disabled.
System Overload/Underload detection doesn’t work below 33.05 value