A1-User’s Manual
168
8.2.28 System
97.01 Initialization mode
0: Clear trip history ----- Initial value
1: Clear all parameters
If set 0, all parameters will reset to initial value except '99.02' (Motor rated voltage)
97.02 Parameter lock mode
0: All parameters are locked except '97.02' by '97.03' ----- Initial value
1: All parameters are locked except '97.02' and '02.01' by '97.03'
2: All parameters are locked except '97.02'
3: All parameters are locked except '97.02' and '20.01'
4: All parameters are locked except '97.02' and '20.01' ,'23.04' ,'23.05'
Related Parameters:
'99.03'
This parameter used to protect that changes parameter by other person
97.03 Software lock source
0: Not selected ----- Initial value
1: Selected
2: DI1
3: DI2
4: DI3
5: DI4
6; DI5
7: DI6
8: DI7
9: DI8
Selects the source of software lock
Set 0: Not selected
Always off
Set 1: selected
Always on
Set 2~9 : DI1~ DI8
It works by digital input which is selected