3FiberCerticationTest
FiberCerticationTestisusedtoevaluatetheperformanceof
beropticcomponentsagainstTIAandISOstandards.These
components include ber optic cable, adapters and splices.
TestPro supports Multi-mode and Single-mode Fiber.
In the eld, launch conditions for Multimode Fiber
AdapterscanbeveriedthoughtheHigherOrderMode
Loss(HOML)test.Thistest-amultimodeberadapter
encircleduxlaunchconditionvericationineld-can
bereadilycreatedintheeldtogaugeandadjustlaunch
conditions through the supplied reference-grade launch
cord.TheHOMLqualicationofthesourceandlaunch
cord combination involves the use of a launch cord with
and without applied mandrel wrap.
a.MultimodeLaunchVerication
Mandrel diameter prescriptions per TIA-526-14-C
Fiber nominal
core diameter
[μm]
50
62.5
900μm
buered ber
[mm (in)]
25 (0.98)
20 (0.79)
1.6mm jacketed
cordage
[mm (in)]
19 (0.75)
24 (0.94)
2.0mm jacketed
cordage
[mm (in)]
23 (0.91)
18 (0.71)
2.4mm jacketed
cordage
[mm (in)]
23 (0.91)
18 (0.71)
3.0mm jacketed
cordage
[mm (in)]
22 (0.87)
17 (0.67)
Note: The mandrel diameters are based on nominal values
of 20 mm (0.79in) and 25mm (0.98in) reduced by the
cordage diameter and rounded up. Mandrel prescriptions
apply to 850nm and 1300 nm sources.
InTestProprole,select[Limit].
Select[TIA].
Select[03MPTL].
Choose appropriate MPTL Limit. To test CAT6A MPTL
limit to test CAT6A link.
Start[Autotest].
Interpret the Pass/Fail result like normal Copper
Certication.
•
•
•
•
•
•
The TestPro CV100 supports
multi-mode and single mode
ber certication test as well as
loopback, dual ended & single
ended test congurations.
TestPro comes preloaded
with TIA, ISO, and loss budget
limits that users can customize
according to their needs.
MandrelWrapfor
Multi-Mode (if required)
Upto2meters
MandrelWrapfor
Multi-Mode (if required)