ESG-D Series Option H98 Signal Generators Softkey Reference
Wideband CDMA Softkeys
Manual Supplement 4-9
Data Insertion
Press this softkey to select how and where the data pattern is inserted
into channel 1.
CRC Appends the selected data pattern to the back of the
CRC. This combination is then convolved, interleaved,
and segmented into timeslots.
Multiplex Segments the selected data pattern directly into
timeslots with Pilot, TPC symbols, and CRC, but
without convolution or interleaving.
Spread Directly spreads the selected data pattern without
segmentation.
The selected data insertion value is bolded. Data insertion is not
selectable for uplink channels 2 and 3.
Softkey Location: Mode > Wideband CDMA > Channel Setup > More (1 of 2) >
Data Insertion
Choices: CRC, Multiplex, or Spread
Status after Normal Preset: CRC
SCPI Commands and Command Queries:
[:SOURce]:RADio:WCDMa[:BBG]:DLINK:CHANnel[1]:INSert
CRC|MULTiplex|SPREad
[:SOURce]:RADio:WCDMa[:BBG]:DLINK:CHANnel[1]:INSert?
[:SOURce]:RADio:WCDMa[:BBG]:ULINK:CHANnel[1]:INSert
CRC|MULTiplex|SPREad
[:SOURce]:RADio:WCDMa[:BBG]:ULINK:CHANnel[1]:INSert?

Table of Contents

Other manuals for Agilent Technologies ESG-D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies ESG-D Series and is the answer not in the manual?

Agilent Technologies ESG-D Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelESG-D Series
CategoryPortable Generator
LanguageEnglish

Related product manuals