Softkey Reference ESG-D Series Option H98 Signal Generators
Wideband CDMA Softkeys
4-14 Manual Supplement
Link Down Up
Press this softkey to toggle the transmission direction between
downlink and uplink. The selected value is bolded. When uplink is
selected, the
Perch Setup softkey is not displayed, and theDown Long Code
softkey is replaced by theUplink Trig Delay softkey. When the signal
generator is in the uplink mode, it must be frequency-locked to the base
station receiver using the uplink trigger feature. Refer to“System
Configurationon page 3-16 and“Rear-Panel Overviewon page 3-11
for additional information.
Softkey Location:
Mode>Wideband CDMA>Link Down Up
Choices:Down orUp
Status after Normal Preset: Down
SCPI Command and Command Query:
[:SOURce]:RADio:WCDMa[:BBG]:CCHannel DLINK|ULINK
[:SOURce]:RADio:WCDMa[:BBG]:CCHannel?
Long Code
Press this softkey to enter the long code for the uplink channels.
In multicode mode, all of the multicodes use the same long code. To
enter the long code value, rotate the front-panel knob until the desired
value is displayed, use the up and down arrow keys, or enter the value
using the numeric keypad and press the
Enter terminator softkey.
Long code value changes are not applied to the waveform until long
code reset, 1280 chips before the end of System Frame Number 2
16
1.
Long code reset only occurs when:
the W-CDMA operating state (
W-CDMA Off On) is toggled,
the transmission link direction (
Link Down Up) is toggled,
the internal System Frame Number transitions from SFN 2
16
1 to
SFN 0,
or when externally triggered by a BTS reference SFN reset input (a
low to high transition at the PATTERN TRIG IN rear-panel
connector).
Other setup changes in uplink mode, such as short code, data rate,
channel type, or time offset, do not affect the long code or long code
phase.
Softkey Location:
Mode>Wideband CDMA>Channel Setup>Long Code
Range: 0 to 1FFFFFFFFFF (hexadecimal)
Status after Normal Preset: 1

Table of Contents

Other manuals for Agilent Technologies ESG-D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies ESG-D Series and is the answer not in the manual?

Agilent Technologies ESG-D Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelESG-D Series
CategoryPortable Generator
LanguageEnglish

Related product manuals