EasyManua.ls Logo

AGR A22 2021 - Battery Parameters; Notice on Battery Usage

AGR A22 2021
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LED5 red, LED6 orange, LED7 white
Red
LED5
Orange
LED6
White
LED7
status Introduction
on Differential pressure alarm: differential
pressure ≤300mv
Please balance
before using
on
Secondary pressure differential alarm:
differential pressure ≥300mv
Please balance
before using
on
Battery voltage is too low Please charge
immediately
flash
Over temperature alarm: 50
≤T≤75
Please cool down
before using
flash
Over temperature secondary alarm:
temperature is higher than 75
Please cool down
before using
on
on Overcharge and other errors Please dont use
9.6. Battery parameters
Item parameter
nominal voltage-nominal voltage 50.4V
nominal voltage 22000mAH
charging voltage 58.8V
charging current
Max57A3C
discharge voltage
49V58.8V
Operating temperature (discharge)
-10℃-+60
Operating temperature (charging)
0℃-+45
storage temperature
-10℃-+35
weight
8.0±0.3KG
Appearance size (length, width and
height)
236.3mm *115.7mm*290.8mm
9
.
7
.
Notice on battery usage
1.
Never disassemble the battery.
2.
Never put the battery into water or fire.
3.
Please use special charger to charge and keep away from high temperature environment.
4.
Do not use batteries that are damaged, leaking, or severely deformed.
5.
It is forbidden to squeeze, bump and short-circuit the battery, so as not to cause unnecessary
losses and safety risks.
6.
Please recharge the battery in time after use, so as not to over-discharge and damage the
battery due to long-term storage
7.
Store the battery in a dry, ventilated environment, and keep away from open flames or
flammable and explosive materials.
8.
It is forbidden to store the battery for leakage. When it is not used for a long time, please keep
the single-cell voltage between 3.8-3.9V. It is recommended to maintain it every three months.

Table of Contents