EasyManuals Logo

Alcatel-Lucent 7210 SAS M Configuration Guide

Alcatel-Lucent 7210 SAS M
516 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #505 background imageLoading...
Page #505 background image
System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 505
Debug Commands
sync-if-timing
Syntax sync-if-timing
Context debug
Description The context to debug synchronous interface timing references.
force-reference
Syntax force-reference {ref1 | ref2}
no force-reference
Context debug>sync-if-timing
Description This command allows an operator to force the system synchronous timing output to use a specific ref-
erence.
Note: This command should be used for testing and debugging purposes only. Once the system tim-
ing reference input has been forced, it will not revert back to another reference at anytime. The state
of this command is not persistent between system boots.
When the debug force-reference command is executed, the current system synchronous timing out-
put is immediately referenced from the specified reference input. If the specified input is not available
(shutdown), or in a disqualified state, the timing output will enter the holdover state based on the pre-
vious input reference.
Parameters ref1 — The clock will use the first timing reference.
ref2 — The clock will use the second timing reference.
system
Syntax [no] system
Context debug
Description This command displays system debug information.
ntp
Syntax [no] router router-name interface ip-int-name

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals