Publication 2098-DU003B-EN-P — September 2006
Ultra3000 Digital Servo Drive Installation Manual 7
Page B-5
Replace the interconnect diagram on page B-5 with the one shown
below. The new diagram changes the recommended wiring of input
fusing, ac line filter, and contactor.
Figure B.3
Typical Power Wiring of Ultra3000 System
(2098-DSD-075x-xx and -150x-xx)
TB1
U
V
W
DC+
DC-
L1
L2
L3
L1 AUX
L2/N AUX
L2
L1
CN1
43
44
L3
TB2
1
2
3
43
44
CN1
43
44
Ultra3000
Digital Servo Drives
2098-DSD-075x-xx and
-150x-xx
Note 13
AC Input Power
Connections
Motor Power
Connections
Three-phase
AC Line Filter
Note 7
Input Fusing *
Note 4, 5
Three-phase Input
100-240V ac (rms)
Fused Disconnect
or Circuit Breaker *
Note 1
Isolation
Transformer *
Note 2
Chassis
Bonded Cabinet
Ground Bus *
Terminal
Blocks *
Note 3
To additional
Ultra3000 drive.
Three-Phase
Motor Power
Connections
Note 12
Cable Shield
Clamp
Note 9
* Indicates User Supplied Component
STOP *
START *
CR1 *
CR1 *
CR1 *
M1 *
Refer to Attention statement (Notes 10, 11)
N.O. Relay Output+
N.O. Relay Output-
Note 20
24V dc
Neutral
Note 6
M1 *
Note 8
External Passive
Shunt Connections
Three-phase AC Line
50/60 Hz
Input Fusing *
Note 4, 5

Table of Contents