Page 162
Not approved by Document Control. For review only.
Allied Telesis
Command Line Interface Users Guide
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the System to basic mode and the trust state.
qos map dscp-queue
The qos map dscp-queue Global Configuration mode command modifies the DSCP to CoS map. Use the no
form of this command to return to the default map.
Syntax
qos map dscp-queue dscp-list to queue-id
no qos map dscp-queue
Parameters
dscp-list — Specifies up to 8 DSCP values separated by a space. (Range: 0 - 63)
queue-id — Specifies the queue number to which the DSCP values are mapped.
Default Configuration
The following table describes the default map.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example maps DSCP values 33, 40 and 41 to queue 1.
qos cos
The qos cos Interface Configuration (Ethernet, port-channel) mode command defines the default CoS value of a
port. Use the no form of this command to return to the default configuration.
Console(config)# qos map dscp-dp 2 4 6 8 10 to 2
DSCP value Queue-ID
00-15 1
16-31 2
32-47 3
48-63 4
Console(config)# qos map dscp-queue 33 40 41
to
1

Table of Contents

Other manuals for Allied Telesis AT-8000S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-8000S Series and is the answer not in the manual?

Allied Telesis AT-8000S Series Specifications

General IconGeneral
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Humidity5% to 95% non-condensing
Switching Capacity104 Gbps
Forwarding Rate77.4 Mpps
VLANs4, 094
Layer 3 FeaturesStatic routing, RIP v1/v2
ManagementWeb-based
Operating Humidity10% to 90% non-condensing

Related product manuals