APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
B-2 990-371
Section II. I/O Connectors
Overview
The control can be configured several different ways in order to match your welding needs. Configuration
is achieved by using the pre-wired Configuration Plug and by fabricating your own I/O cables using three
un-wired plugs. All of these connectors are supplied in the Ship Kit. Complete connection information
is in Section III, I/O Configuration.
Before fabricating I/O cables, you should be familiar with the physical characteristics of the Power
Supplies I/O connectors.
60-Pin Connector
The 60
-pin I/O connector is located on the Power
Supplies
rear panel as shown on the right. This
connector can accommodate six 10
-pin plugs,
including the factory
-supplied Configuration
Plug
.
Selected pins contain red inserts as shown below. These inserts prevent properly configured 10-pin plugs
from being plugged into the wrong sections of the 60-pin connector.