CHAPTER 3: SYSTEM CONFIGURATION
HF-2500A HIGH FREQUENCY WELD CONTROL
3-14 990-371
5. Language
Press the 5 key to toggle between English and German. All menu items and instructions on the screen
will be in the language selected.
Setup 3
1. DO TEST WELD
In voltage mode, the unit will do a test weld to optimize response to varying weld conditions. Press 1 to
bring up the following choices:
1) ALWAYS
A test weld will be done if:
The voltage level changes
The time in any element of the schedule changes
If the weld energy field is highlighted and the V key is pressed.
2) ASK
The user will be prompted to choose if a test weld is done or not upon the following conditions:
The voltage level changes
The time in any element of the schedule changes
If the weld energy field is highlighted and the V key is pressed.