APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
E-14 990-371
OHMS number_of_data <crlf>
data <crlf> data <crlf> . . . . data <crlf><lf>
Returns the Resistance waveform data of the last weld. First field is the number of data to be
sent. Then follows the packets of data. Each data is separated by <crlf> and this command ends
with <crlf><lf>.
number_of_data:
This is the number of data that shall be included in this Command. The
Power Supply samples Current and Voltage every 40 µs. For a weld less than 80
time, the number of data will be approximately: total weld time ÷ 40
µ
s.
be always less than 2000.
data: An integer number in unit of mOhms.
Power Supply return SYNC command back to the h
ost computer when the SYNC command
is received from the host computer.
{ light_value }<crlf>
{ OFF | ON }<crlf>
{ loudness_value }<crlf>
{ PEAK | AVG }<crlf>
{ switch_state }<crlf>
{ switch_state }<crlf>
{ AUTO | REMOTE | NONE } <crlf>
{ AUTO | OPTO | NONE } <crlf>
{ OFF | ON } <crlf>
{ OFF | ON } <crlf>
{NONE | 10 | 20 | 30 } <crlf>
tings of the Power Supply system parameters.
is a number 0 to 99 for brightness of the LCD. 0 is dark and 100 is the brightest.
is a number 0 to 99 for buzzer loudness. 0 is off and 100 is the loudest.
{ MECHOPEN | MECHCLOSED | OPTOOPEN
| OPTOCLOSED | PLC0V | PLC24V}