Installation Procedures: 12" and 15" Panels
50
Modero VG Series Touch Panels - Instruction Manual
3. Remove the magnetic faceplate/bezel (A in FIG. 42) from the main NXD unit (B in FIG. 42) by gripping the faceplate and pulling
with gentle outward force.
4. Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal locations) through the
cutout opening. Refer to the Wiring Guidelines for the 1200VG and 1500VG Panels section on page 56 for pinout descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5. Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered) NXD touch
panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin power
connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
6. Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify the panel is
receiving power and functioning properly to prevent repetition of the installation.
7. Disconnect the terminal end of the power cable from the connected power supply.
NOTE: Don’t disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before
being inserted into the drywall.
8. Insert the four sets of drywall screws and expansion clips into the four oval notch locations along the top/bottom edges of the
main unit (FIG. 41).
9. Carefully insert the main unit (with expansion clips) into the cutout until the Mounting Tabs on the NXD unit lie flush against
the wall (FIG. 41).
10. Tighten the drywall clip sets (screws and clips) until the Mounting Tabs are securely fastened and flush against the wall.
FIG. 41
NXD-1500VG 15-inch Wall Mount panel dimensions using expansion clips
FRONT BEZEL
*
CUTOUT
*
* Notches are NOT
SYMMETRICAL