Section 5 GPIB
5-16
(6) G
1) GTEND gate end
Determines whether the carrier frequency measurement range is to be extended to the end of the gate width
specified by the gate width parameter or to the end of the burst.
Command : GTEND n
Query : GTEND?
Response : GTEND n
<Program data>
Value of n
0 .......................... Off (initial value: until the end of the burst)
1 .......................... On (Until the end of the gate width. Note that when the burst ends before the end of the gate
width, the measurement will be to the end of the burst.)
2) GTWDT gate width
Sets the gate width.
Command : GTWDT n
Query : GTEDT?
Response : GTWDT n
<Program data>
Value of n
100 × 10
–9
to 100 × 10
–3
(sec) .... Suffix : NS, US, MS, S, N, U, M (Unit sec)
Note that the value set n is in 20 ns increments from 100 ns to 1 µs and two significant digits between 1 µs and 100
ms. Values set outside those ranges will be rounded down.
(7) I
1) INPCH input channel
Selects the terminal to which to input the signal.
Command : INPCH n
Query : INPCH?
Response : INPCH n
<Program data>
Value of n Value set
1 .......................... CHANNEL 1 (initial value)
2 .......................... CHANNEL 2