User Manual
38
duplication of authentication of users. The default is disabled.
[Ring function]: It is disabled by default, according to the actual needs of their own settings
(This feature applies to support a bell function of the model).
[Wiegand Mode]: There are two modes: Encrypted Anviz wiegand, wiegand 26, fixed wiegand
area code and card number mode wiegand. Default Wiegand 26 (for supported Wiegand
outputs of attendance).
[Fixed Wiegand area code]: If you upload the same fingerprint ID number to two different
machines than by wiegand signal output after the number will be different. Wiegand code set at
this time if these two machines of the same words, wiegand signal output on the same number.
[Relay time]: Means connected with the lock to open the door after attendance by relay. The
maximum delay of 15 seconds (for support electric lock signal output attendance).
After setting, click [OK] button to save the settings.
5.1.6 Access Setting
Group management for door open timetable support access control function support devices,
This function is only for the terminals which have the access control output.
Anviz crosschex software support 32 access control timetable and 16 access control group,
one group support 4 timetables, the target is to setup access timetable to staff, and connect all
timetable to a access rule, and give rights to the according staff.
Steps to setup
1Setup time zone list
In the list, show first timetable1-Day
The time list show Monday to Friday7001900in this period, the staff could accessed.
You can change and set the according 32 time zone and Apply to the system.
2Setup access group
In the list has 0-NC Group and 1-NO Group could not be modified.