Main Controls 91
Power
BAT1 (Plug)
warning
The level at which a power warning is exhibited for
the power source connected to the BAT plug. Can be
adjusted to match the used battery type. Default
value is 21.0 V.
BAT2
(Onboard)
warning
The level at which a power warning is exhibited for
the onboard battery. Can be adjusted to match the
used battery type. Default value is 12.0 V.
Note: At a level 10% below the set warning level, a battery error is emitted. This
means that the power source is treated as insufficient to power the camera and
recording is prohibited.
Figure 70: MENU>SYSTEM>POWER
Smart batteries that transmit their remaining load to the camera emit a
warning at 10% remaining capacity and an error at 5% remaining capacity.
Currently batteries by ID-X, Bebop, Anton Bauer and any battery using the
TI-protocol support this feature.
External Sync
Eye index The first letter of the Camera ID can be changed
between L and R for stereoscopic productions to
identify left and right eye camera. Influences naming
of clips on SxS cards.
Sensor sync The sensors of 2 ALEXA cameras can be synced.
See Sensor sync (on page 114) for more info.
Off: The camera is in non-synced mode for regular
use.
EXT master: The camera sends signals to an EXT
SLAVE camera via the EXT connector containing
sync clock and TC signals.
EXT slave: The camera listens on the EXT
connector to signals from an EXT MASTER
camera containing sync clock and TC signals.
HD out phase The phase of the HD out can be adjusted in the range