2 2
1
2
• Tuesday
• Circuit 2 in use for domestic hot water
• Heat Pump running at third power
level
• Water temperature at leaving point
(of primary domestic water circuit):
62°C
• Pressure: 1.3 bar
Example 1
1 . 3 b a r
6 2
°C
2 2
2
2
1 1
• Thursday
• Holiday mode in progress
• Holiday mode set to end in 14 days
Example 2
h o l i . r e t u r
1 4 d
4
• Once the appliance has been switched on, or if the control box
hasn’t been used for more than 30 minutes, the control box will
automatically lock. When in locked mode, the buttons become
inactive.
• To unlock the control box, press
and hold
down for 4 seconds.
Select language
Enter
L A N G U AG E
E N G
• Press .
• Turn dial to scroll through menu choices:
• Press
to return to main screen.
4.1.4 - Language
4.2 - Installer Menu
Accessing the installer menu:
• Press
• Turn dial until "INST. MEnu"appears on screen
• Press
and
• Hold them down simultaneously for 3 sec.
- back up - data calculations
- configuration - counters
- Settings - manual
- display - reset paramEtres
Access:
- values measured
- temperatures calculated
- programmed time periods
- counters / meters
4.2.1 - Selecting the right back-up for the
installation
ba c k up
H p o n ly
H P + bo i l e r
H p + el e c t
bo i l e r
e l e c t ri c
Enter
Enter
Enter
Enter
Enter
• Access choice of appliances
authorised to run
Heat Pump only running, no
back-up (default setting)
Heat Pump running with back-
up from existing boiler
Heat Pump running with
integrated 6kW electrical
back-up
Back-up operation mode
using only existing boiler (for
temporary forced command)
Back-up operation mode
using only 6kW electrical
back-up (for temporary forced
command)