EasyManua.ls Logo

auer HRC70 - HRC HEAT PUMP - 11 Kw Three Phase- Internal Wiring Diagram

auer HRC70
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- INSTALLER 7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
70
HRC
70
HEAT PUMP - 11 kW three phase- internal wiring diagram
TsPAC : Water outlet temperature sensor
TePAC : Water inlet temperature sensor
Tdégiv : De-icing temperature sensor
Tair : Air inlet temperature sensor
Tcomp : Compressor temperature sensor
HP : Compressor high pressure switch
BP : Low pressure switch
CP : Compressor start-up command
VEM : De-icing solenoid valve cycle inversion
command
CH : Compressor RK heater cable
CC : External heater cable
VO : Fan control
F : 5x20 4A fuse
K : Compressor thermal protection device
CS : Compressor start-up
RK : Compressor crank case heater
EV : De-icing solenoid valve

Table of Contents