- INSTALLER 7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
70
HRC
70
HEAT PUMP - 11 kW three phase- internal wiring diagram
TsPAC : Water outlet temperature sensor
TePAC : Water inlet temperature sensor
Tdégiv : De-icing temperature sensor
Tair : Air inlet temperature sensor
Tcomp : Compressor temperature sensor
HP : Compressor high pressure switch
BP : Low pressure switch
CP : Compressor start-up command
VEM : De-icing solenoid valve cycle inversion
command
CH : Compressor RK heater cable
CC : External heater cable
VO : Fan control
F : 5x20 4A fuse
K : Compressor thermal protection device
CS : Compressor start-up
RK : Compressor crank case heater
EV : De-icing solenoid valve