Introduction
The DL205 CPUs offer a wide variety of instructions to perform many different types of
operations. There are several instructions that are not available in all of the CPUs. This
chapter shows you how to use these individual instructions. There are two ways to quickly
find the instruction you need.
• If you know the instruction category (Boolean, Comparative Boolean, etc.), use the header at the
top of the page to find the pages that discuss the instructions in that category.
• If you know the individual instruction name, use the following table to find the page that discusses
the instruction.
Instruction Page
BIN Binary 5–130
BCALL Block Call (Stage) 7–27
BEND Block End (Stage) 7–27
BLK Block (Stage) 7–27
BTOR Binary to Real 5–134
CMP Compare 5–83
CMPD Compare Double 5–84
CMPF Compare Formatted 5–85
CMPR Compare Real Number 5–87
CMPS Compare Stack 5–86
CMPV ASCII Compare 5–221
CNT Counter 5–46
COSR Cosine Real 5–121
CV Converge (Stage) 7–25
CVJMP Converge Jump (Stage) 7–25
DATE Date 5–175
DEC Decrement 5–100
DECB Decrement Binary 5–108
DECO Decode 5–129
DEGR Degree Real Conversion 5–136
DISI Disable Interrupts 5–188
DIV Divide 5–97
DIVB Divide Binary 5–106
DIVBS Divide Binary Top of Stack 5–120
DIVD Divide Double 5–98
DIVF Divide Formatted 5–112
DIVR Divide Real Number 5–99
DIVS Divide Top of Stack 5–116
DLBL Data Label 5–199
DRUM Timed Drum 6–12
EDRUM Event Drum 6–14
ENCO Encode 5–128
END End 5–177
ENI Enable Interrupts 5–188
Instruction Page
ACON ASCII Constant 5–199
ACOSR Arc Cosine Real 5–122
ACRB ASCII Clear Buffer 5–229
ADD Add BCD 5–88
ADDB Add Binary 5–101
ADDBD Add Binary Double 5–102
ADDBS Add Binary Top of Stack 5–117
ADDD Add Double BCD 5–89
ADDF Add Formatted 5–109
ADDR Add Real 5–90
ADDS Add Top of Stack 5–113
AEX ASCII Extract 5–220
AFIND ASCII Find 5–217
AIN ASCII IN 5–212
AND And for contacts or boxes 5–14, 5–32, 5–71
AND STR And Store 5–16
ANDB And Bit–of–Word 5–15
ANDD And Double 5–72
ANDE And if Equal 5–29
ANDF And Formatted 5–73
ANDI And Immediate 5–35
ANDMOV And Move 5–171
ANDN And Not 5–14, 5–32
ANDNB And Not Bit–of–Word 5–15
ANDND And Negative Differential 5–23
ANDNE And if Not Equal 5–29
ANDNI And Not Immediate 5–35
ANDPD And Positive Differential 5–23
ANDS And Stack 5–74
ASINR Arc Sine Real 5–121
ATANR Arc Tangent Real 5–122
ATH ASCII to Hex 5–137
ATT Add to Top of Table 5–166
BCD Binary Coded Decimal 5–131
BCDCPL Tens Complement 5–133

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automationdirect.com DirectLOGIC DL205 Series and is the answer not in the manual?

Automationdirect.com DirectLOGIC DL205 Series Specifications

General IconGeneral
BrandAutomationdirect.com
ModelDirectLOGIC DL205 Series
CategoryController
LanguageEnglish

Related product manuals