Multiply Formatted (MULF)
Multiply Formatted is a 16-bit instruction that multiplies the
BCD value in the accumulator by the BCD value (Aaaa)
which is a range of discrete bits. The specified range (Kbbb)
can be 1 to 16 consecutive bits. The result resides in the
accumulator.
NOTE: Status flags are valid only until another instruction uses the same flag.
In the following example, when X6 is on, the value formed by discrete locations X0–X3 is
loaded into the accumulator using the Load Formatted instruction. The value formed by
discrete locations C0–C3 is multiplied by the value in the accumulator using the Multiply
Formatted instruction. The value in the lower four bits of the accumulator is copied to
Y10–Y13 using the Out Formatted instruction.
Discrete Bit Flags Description
SP63 On when the result of the instruction causes the value in the accumulator to be zero.
SP70 On anytime the value in the accumulator is negative.
SP75 On when a BCD instruction is executed and a NON-BCD number was encountered.
LDF X0
K4
X6
Load the val ue represented
by discrete locations X0 --X3
into the accum ulator
MULF C0
K4
Multi pl y the value in the
accum ul ator with the value
represented by di screte
locations C0 --C3
OUTF Y10
K4
Copy the l ow er 4 bits of the
accum ul ator to discrete
locations Y10 --Y13
060 000 0
000
0
0 0003
(C0--C3)
(Accumulator )
2
X0X1X2X3
ONONOFFOFF
C0C1C2C3
OFFONOFFOFF
Y10Y11Y12Y13
OFFONONOFF
The unused accum ulator
bits are set to zero
Acc.
Handheld Programmer Keystrokes
STR
$
SHFT
ISG
U
ANDST
L
OUT
GX
SHFT
5
F
0
A
4
E
ENT
6
G
ENT
1
B
4
E
0
A
ENT
SHFT
ANDST
L
3
D
0
A
4
E
ENT
5
F
5
F
ORST
M
NEXT NEXT NEXTNEXT
X
DirectSOFT
Operand Data Type DL260 Range
A aaa bbb
Inputs X 0-1777 -
Outputs Y 0-1777 -
Control Relays C 0-3777 -
Stage Bits S 0-1777 -
Timer Bits T 0-377 -
Counter Bits CT 0-377 -
Special Relays SP 0-777 -
Global I/O GX/GY 0-3777 -
Constant K - 1-16
DS Used
HPP Used