Q5X With Dual Discrete Outputs And IO-Link Instruction Manual
41
Typical Excess Gain for the 10000 mm Model
Typical Excess Gain Using a 90% White Card
at 50
mm
at 600
mm
at 1000
mm
at 2000
mm
at 5000
mm
at 6000
mm
at 7500
mm
at
10000
mm
50 400 400 175 30 20 10 5
Excess gain is consistent for 15, 50, and 250 ms response
speeds. Excess gain is approximately 10% lower in 2 ms and
5 ms response speed modes.
Excess gain in black gain mode is approximately three times
higherthaninperformancegainmode.Itisusefulforlowre
flectivity targets.
Excess gain in shiny gain mode is approximately one-third the
excess gain of performance gain mode values. It is useful for
highly reflective targets.
Beam Spot Size
x
y
Beam
Spot
Pattern
BeamspotsizesaremeasuredX×Ymmatspecificdis
tances.
2000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
3000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
7.8×4.7mmat3000mm
5000 mm Models:
6×4mmat100mm
11×7mmat2500mm
15×11mmat5000mm
10000 mm Models:
7×6mmat100mm
16×11mmat2500mm
25×19mmat5000mm
32×25mmat7500mm
41×31mmat10000mm
Beamspotsizeiscalculatedas1.6timestheD4σmeasured
value
Certifications
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Class2power;ULEnvironmentalRating:Type
1
VCCI-CISPR 32
Required Overcurrent Protection
WARNING: Electrical connections must
bemadebyqualifiedpersonnelinac
cordancewithlocalandnationalelectri
calcodesandregulations.
Overcurrentprotectionisrequiredtobeprovidedbyendprod
uctapplicationperthesuppliedtable.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
towww.bannerengineering.com.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 1.0 30 0.5