Field Service Manual December 2003
Page 105 of 276
limit
P970 0 1 = reset (P10=30)
P1000 1 Selection of frequency
setpoint:
1 MOP setpoint (par
1040)
3 Fixed frequency
setpoint
P1001 0 Fixed frequency 1 DIN 1
P1040 40 Hz = first fixed
frequency
P1082 60 Hz max freq
P1080 0 Min speed
P1120 20 Sec ramp up
P1121 15 Sec ramp down
P1135 15 Off3 ramp-down time
(emergency stop)
P1215 1 enable mech break
P1217 5.0 Sec
P1232 100 DC braking current
P1233 3 Dc braking time
6seconds
P1234 5 Hz moment when dc
braking is activated
P1237 4 During break 50% is
dissipated in Brake
resistor.
P1300 0
P1910 (1) Motor calibration should
be done once
P2106 52.b Diagnostic level
P3900 0 3 = motor parameters
This has to be done to
make the parameter
changes effective.
* only changeable in quick commissioning mode.
For RS485 connecting:
P1000 5
P2000 40 (for 25rps from this value the other drum speeds are
made)
P2012 2 USS PZD length
P2013 3 USSPKW length
P2011 1 USS address
P2010 6 USS baudrate
WARNING :
change of parameter 700
all involved parameters are reset to default values !