Field Service Manual December 2003
Page 140 of 276
27 Delayclk freq. (ppi)
Automatic retrieved
28 Horizontal offset (pixels) : 0
- Vertical distance from the top left corner of the
largest film size to the first pixel exposed on the
film for an exposure where no quadding is done.
29 Vertical offset (scanlines) 0
- Horizontal distance from the top left corner
of the largest film size to the first pixel
exposed on the film for an exposure where no
quadding is done.
71 Vac off time after load 28''(ms): 7000
Vacuun off after loading for film relaxation for 28” around drum
72 Vac off time after load 27''(ms): 7000
Vacuun off after loading for film relaxation for 27” around drum
73 Vac off time after load 26''(ms): 7000
Vacuun off after loading for film relaxation for 26” around drum
74 Time out at drawer empty (ms) : 432000000
Time the machine waits after he detected a empty cassette. After this time the
machine drops out with a ‘cassette empty’ error message.
75 Minimum beams to expose : 1
76 Chart home pos filmt1 (1/6400 mil) :97500000
- defines the origin of the film along the drum for filmt1 (setting 1xx)
For adjustment of this value see explanation at parameter 3
77 Chart home pos filmt2 (1/6400 mil): 97500000
- defines the origin of the film along the drum for filmt2 (setting 2xx)
For adjustment of this value see explanation at parameter 3
78 Chart home pos filmt2 (1/6400 mil): 97500000
- defines the origin of the film along the drum for filmt3 (setting 3xx)
For adjustment of this value see explanation at parameter 3