Field Service Manual December 2003
Page 144 of 276
Special options
There are 11 sets of parameters that can be seen by typing a special
character.
B : machine configuration
P : PID parameters carriage
F : filmfeed parameters
M : freq. and delay for base resolution
A : multibeam amplitude - tune corrections
O : supported resolution
N : beam pin configuration
T : thicknesses per filmtype
I : diagnostic level
G : Drumspeed and Resolution table
C : freq. and delays in testjobmode
E : Listing of expose parameters
Parameter ver 8.0 your choice: B
24 beam
Dpi = 2000 Bms = 24 Dpi = 4000 Bms = 24
Dpi = 4064 Bms = 24 Dpi = 8000 Bms = 24
Dpi = 8128 Bms = 24 Dpi = 16000 Bms = 24
Dpi = 20000 Bms = 24 Dpi = 20320 Bms = 24
-Dpi : Resolutions are coming from the O-table.
-BMS : D
efines the number of beams the optic is adjusted for.
- Multiformat feeder : Y or N
- Unload in drawer : Y or N
Online switch on
II for unloading in developer :
Y : when film stays on top of online sensor, SW keeps exposing and will
unload all films in unload drawer.
N : when film stays on top of online sensor, SW will unload film in unload
drawer and stops with exposing.
- MicroMaster RS485 : Y or N
-RS485(cable) connection between MACBPL and drum micromaster.
- Load with spindle : Y or N
-MultiFilmFeeder plate moved by spindle?(or by cable)
- Eph2 : 2048
- For maccon 2048