Checking the restlight
Switch off all the beams
LTL>alloff
Open shutter
LTL>shinit
LTL>shopen
Connect your multimeter to the diod and skip the optic in front of the
the diod.
LTL>22 gpar skipa
no rest light should be present:
intensity measured < 0,04 µA DC
Remark :
If restlight is bigger then 0,04µA clean optic parts. Especially the
modulator. (Clean with aceton)
Shutter