Baumer GenICam Camera Features | 11
V1.2 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2 Operating Manual 115
11.7.4 CounterReset
Executes software reset and start of the selected Counter. Counter starts counting events im-
mediately after reset unless Counter Trigger trigger is active. CounterReset is to reset Counter
independently of CounterResetSource. To disable Counter temporarily, set Coun-
terEventSource = Off.
INFO
Note that the value of Counter at time of reset is automatically saved and reflects in CounterVal-
ueAtReset.
Name CounterReset
Category CounterAndTimerControl
Interface ICommand
Access Write only
Unit -
Values -
11.7.5 CounterResetActivation
Selects the activation mode of the CounterResetSource signal.
Name CounterResetActivation
Category CounterAndTimerControl
Interface IEnumeration
Access Read / Write
Unit -
Values RisingEdge Resets the counter on the rising edge of the signal.
FallingEdge Resets the counter on the falling edge of the signal.
AnyEdge Resets the counter on the falling or rising edge of the selected
signal.
11.7.6 CounterResetSource
Selects the signals that will be the source to reset Counter.
Name CounterResetSource
Category CounterAndTimerControl
Interface IEnumeration
Access Read / Write
Unit -
Values see table(s) below