Baumer GenICam Camera Features | 11
V1.2 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2 Operating Manual 87
11.1.17 TriggerActivation
Specifies the activation mode of the trigger.
Name TriggerActivation
Category AcquisitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values FallingEdge Trigger valid at falling edge of source signal.
RisingEdge Trigger valid at rising edge of source signal.
11.1.18 TriggerDelay
Specifies the delay in microseconds (µs) to apply after the trigger reception before activating it.
Name TriggerDelay
Category AcquisitionControl
Interface IEnumeration
Access Read / Write
Unit µs
Values 0 - 2,000,000.000000 (Increment: 1.00)
11.1.19 TriggerMode
Controls if the selected Trigger is active.
Name TriggerMode
Category AcquisitionControl
Interface IEnumeration
Access Read / Write
Unit -
Values Off Disables selected Trigger.
On Enables selected Trigger.
Rolling Shutter cameras
With cameras featuring Rolling Shutter sensor,TriggerMode depends on SensorShutterMode.
Trigger Mode = On Trigger Mode = Off
ShutterMode ReadoutMode ShutterMode ReadoutMode
GlobalReset Non-overlapped GlobalReset Non-overlapped
Rolling Non-overlapped Rolling Overlapped