EasyManua.ls Logo

Baumer VCXG.2 Series - Devicetlversionsubminor; Devicetemperature; Devicetemperatureexceeded; Devicetemperatureselector

Baumer VCXG.2 Series
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Baumer GenICam Camera Features | 11
V1.2 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2 Operating Manual 129
11.9.28 DeviceTLVersionSubMinor
Minor version of the Transport Layer (GigE Vision
®
version) of the device.
Name DeviceTLVersionSubMinor
Category DeviceControl
Interface IInteger
Access Read only
Unit -
Values ≥ 0 (x.x.X)
11.9.29 DeviceTemperature
Device temperature in degrees Celsius (°C). Measured at the location selected by DeviceTem-
peratureSelector.
Name DeviceTemperature
Category DeviceControl
Interface IFloat
Access Read only
Unit °C
Values Device specific (e.g. -127.0 ... 127.0)
11.9.30 DeviceTemperatureExceeded
Returns if the device operates in critical temperature range.
Name DeviceTemperatureExceeded
Category DeviceControl
Interface IBoolean
Access Read only
Unit -
Values true = 1 (On)
false = 0 (Off)
11.9.31 DeviceTemperatureSelector
Selects the temperature measuring point.
Name DeviceTemperatureSelector
Category DeviceControl
Interface IEnumeration
Access Read / Write
Unit -
Values InHouse Temperature inside the camera housing.

Table of Contents