Baumer GenICam Camera Features | 11
V1.2 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2 Operating Manual 129
11.9.28 DeviceTLVersionSubMinor
Minor version of the Transport Layer (GigE Vision
®
version) of the device.
Name DeviceTLVersionSubMinor
Category DeviceControl
Interface IInteger
Access Read only
Unit -
Values ≥ 0 (x.x.X)
11.9.29 DeviceTemperature
Device temperature in degrees Celsius (°C). Measured at the location selected by DeviceTem-
peratureSelector.
Name DeviceTemperature
Category DeviceControl
Interface IFloat
Access Read only
Unit °C
Values Device specific (e.g. -127.0 ... 127.0)
11.9.30 DeviceTemperatureExceeded
Returns if the device operates in critical temperature range.
Name DeviceTemperatureExceeded
Category DeviceControl
Interface IBoolean
Access Read only
Unit -
Values true = 1 (On)
false = 0 (Off)
11.9.31 DeviceTemperatureSelector
Selects the temperature measuring point.
Name DeviceTemperatureSelector
Category DeviceControl
Interface IEnumeration
Access Read / Write
Unit -
Values InHouse Temperature inside the camera housing.