EasyManua.ls Logo

Baumer VCXG.2 Series - Page 84

Baumer VCXG.2 Series
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 | GenICam Camera Features Baumer
84 Operating Manual VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2 | V1.2
VCXU.2
Texposure
min
[μsec]
1)
Tnon-
selectable
range
2)
[μsec]
Texposure
min
[μsec]
(Default)
Texposure
max
[sec]
Monochrom
VCXU.2-13.M - - 20 1
VCXU.2-15.M 1 - 15 60
VCXU.2-31.M 1 - 15 60
VCXU.2-32.M 1 - 15 60
VCXU.2-50.M 1 - 15 60
VCXU.2-50.MP 1 - 15 60
VCXU.2-51.M 1 - 15 60
VCXU.2-57.M 1 4 - 9 10 60
VCXU.2-65.M.R - - 10* / 22** 10.16* / 60**
VCXU.2-123.M 1 - 15 60
VCXU.2-127.M 1 4 – 14 15 60
VCXU.2-201.M.R - - 29* / 29** 60* / 60**
VCXU.2-241.M 1 4 - 16 17 60
Color
VCXU.2-13.C - - 20 1
VCXU.2-15.C 1 - 15 60
VCXU.2-31.C 1 - 15 60
VCXU.2-32.C 1 - 15 60
VCXU.2-50.C 1 - 15 60
VCXU.2-51.C 1 - 15 60
VCXU.2-57.C 1 4 - 9 10 60
VCXU.2-65.C.R - - 10* / 22** 10.16* / 60**
VCXU.2-123.C 1 - 15 60
VCXU.2-127.C 1 4 - 14 15 60
VCXU.2-201.C.R - - 29* / 29** 60* / 60**
VCXU.2-241.C 1 4 - 16 17 60
1)
only if ShortExposureTimeEnable is enabled
2)
Range (ExposureTimeGapMinExposureTimeGapMax) only relevant if ShortExposure-
TimeEnable is enabled
*) Shutter Mode: Global Reset
**)Shutter Mode: Rolling Shutter (Default)