Table of Contents

Questions and Answers

  • M
    Martin AdamsSep 15, 2025
    What to do if Bayrol PoolManager PRO dosing pump is running, but there is no redox correction?
    • M
      Michael HarrisSep 15, 2025
      If the dosing pump is running but there is no redox correction, it could be because: * The container is empty, so you should replace the maintenance product. * The dosing pump has sucked in air and is no longer dosing, so you should remove air from dosing head.
  • W
    William EllisAug 25, 2025
    What to do if the Bayrol Water System dosing pump continues to run despite the unit showing a dosing output of 0%?
    • L
      Lisa MeltonAug 25, 2025
      If the dosing pump continues to run even when the unit displays a 0% dosing output, the fuse on the dosing pump might be burnt. Replace the fuse (2SB). Another possible cause is a defective dosing relay, which would require replacing the respective relay. Finally, the dosing pump itself may be defective and need replacement.
  • H
    hudsonmonicaAug 26, 2025
    What to do if the Bayrol Water System dosing pump is not running despite the unit showing dosing output?
    • A
      Amber StevensonAug 26, 2025
      If the dosing pump isn't running even though the unit indicates dosing output, the fuse on the dosing pump may be burnt, needing replacement (2SB). Alternatively, the dosing relay could be defective, requiring replacement of the respective relay. In some cases, the dosing pump itself might be defective and require replacement.
  • V
    Virginia HannaAug 26, 2025
    What to do if the Bayrol Water System unit shows a dosing output of 0% although there is a deviation between actual value and setpoint?
    • L
      lance85Aug 26, 2025
      If the unit displays a 0% dosing output despite a difference between the actual value and the setpoint, it could be due to an alarm blocking the dosing process. This could be a flow, level, or dosing time alarm. You should remediate the cause of the alarm and then acknowledge the alarm.
  • D
    Danny DavisSep 16, 2025
    Why do pH control measurement and unit display show different values on my Bayrol Lighting Equipment?
    • S
      Susan DrakeSep 16, 2025
      If the pH control measurement and the unit display show different values, it is possible that the calibration is erroneous or was performed a long time ago. In this case, you should perform a new calibration.
  • A
    Amanda SmithSep 23, 2025
    What causes calibration failure in redox calibration for Bayrol PoolManager PRO?
    • T
      Todd MullenSep 23, 2025
      Calibration failure during redox calibration could occur due to: * Erroneous entry of calibration values. Repeat the calibration. * The electrode being contaminated or defective. Use sensor cleaner or 5-10% hydrochloric acid to clean the electrode, then rinse with distilled water. If the electrode still doesn't calibrate, it needs to be replaced. * Moisture in the cable. Dry or replace the cable. * A defective measurement amplifier. The device needs to be repaired or replaced.
  • G
    gsmithSep 8, 2025
    What to do if the Bayrol PoolManager PRO dosing pump continues to run despite the unit showing a dosing output of 0%?
    • K
      katherinecoxSep 8, 2025
      If the dosing pump continues to run even when the unit displays a 0% dosing output, it could be due to several reasons: * The fuse on the dosing pump might be burnt, in which case you should replace the fuse (2SB). * The dosing relay could be defective, requiring you to replace the relay. * The dosing pump itself might be defective, necessitating its replacement.
  • A
    Angela BryantSep 8, 2025
    Why is the Bayrol Lighting Equipment dosing pump not running despite the unit showing dosing output?
    • M
      marshwilliamSep 8, 2025
      If the dosing pump is not running even though the unit indicates dosing output, it could be due to a few reasons: * The fuse on the dosing pump might be burnt, so replace the fuse (2SB). * The dosing relay could be defective, requiring you to replace the respective relay. * The dosing pump itself might be defective, in which case you should replace it.
  • S
    Sarah AbbottSep 2, 2025
    How to fix Bayrol Water System redox potential deviates from setpoint over a longer period of time?
    • C
      Craig VaughanSep 2, 2025
      If the redox potential deviates from the setpoint over a longer period, it indicates that the redox control dosing output is too low. To fix this, set a lower value for the p'range, which will increase dosing output. Increasing the minimum switch-on time will also help the setpoint to be reached more quickly.
  • J
    Jesse RomeroAug 31, 2025
    Why Bayrol Water System unit does not trigger dosing at the expected point in time?
    • S
      Shawn ColeAug 31, 2025
      If the unit isn't triggering dosing at the expected time, it may be due to an alarm blocking the dosing, such as a flow or level alarm. To fix this, remediate the cause of the alarm and then acknowledge the alarm.

Summary

Measurement Graph and Water Maintenance

Water Maintenance and Disinfection

Covers pH value importance and disinfection methods for optimal pool water quality.

Measurement, Control, and Dosing

Calibration Procedures

Calibration Necessity and pH Calibration

Outlines when calibration is needed and details the pH electrode calibration process.

Chlorine, Bromine, and Redox Calibration

Describes calibration procedures for chlorine, bromine, redox measurements, and determining the redox setpoint.

Automatic Dosing and Temperature Measurement

Automatic O2 (Bayrosoft) Dosing

Explains the automatic dosing concept for Bayrosoft®, including main, refresh, and additional dosages.

Manual Dosing and Safety Functions

Manual Dosing Operations

Explains the option to add product manually for various modules and how to access manual dosing.

Safety Functions and Alarm Monitoring

Details monitored alarm statuses like flow, level, and value alarms, and how they affect operation.

Controller Settings and User Management

User Management and Access Control

Explains user administration, access rights, remote access configuration, and user level adjustments.

Universal Switch Outputs

Safety Information and Overview

Provides safety warnings for switch outputs and an overview of their features.

Filter Pump and Flockmatic Pump Control

Filter Pump Control Procedures

Covers safety, overview, and configuration menus for filter pump control.

Heating and Solar Heating Systems

Heating System Control

Covers overview, temperature measurement, function, and menu settings for heating control.

Solar Heating System Control

Details the overview, function, and menu configuration for controlling a solar heating system.

Salt Electrolysis and Eco Mode Functions

Salt Electrolysis Control

Covers menu configuration and electrical connection for salt electrolysis systems.

Eco Mode (Energy Saving Mode)

Explains the Eco mode function, its menu, and basic configuration for energy saving.

Installation and Electrical Safety

Safety Information for Installation

Provides critical safety information and hazards related to installation, start-up, and maintenance.

System Installation and Maintenance Procedures

Service Measures and Maintenance Tasks

Details monthly, quarterly, and annual maintenance tasks, cleaning, and replacing pump hoses.

Dosing Pumps and Care Method Updates

Network Connection and Remote Access

Internet Remote Access and Security

Unit Service Measures

Bayrol PoolManager PRO Specifications

General IconGeneral
BrandBayrol
ModelPoolManager PRO
CategoryLighting Equipment
LanguageEnglish

Related product manuals