13.7 Configuration List
152
Function Range Default Values Customer Set Up
Measuring Parameter
Detector Code 0 - 50 0
Isotope Co/Cs/Am/Cm/
Kr/Sr
Co-60
Time Costant 1 bis 9999,9 s
Belt Speed 0 - 99,99 m/s 1 m/s
Current Input - 0 – 20 mA
- 4 – 20 mA
Current Input
Limits
0 – 99 m/s (0 – 99 %) 0 - 2
Max.
Basis Weight
0 – 90,000 g/cm² 0,000
Belt Width 0 - 9,99 m 1
Product Selection -external
-internal
internal
Low Load 0 – 99.999 t 0
Erase
Mass Integrator
yes/no no
I/O Config
Product Selection 1-10 1
Current Output - 0-20 mA /
- 4-20 mA
0 -20 mA
Current Output
Limits 0/4mA
0 - 99999.9 0 t/h (kg/h)
Current Output
Limits 20mA
0 - 99999.9 100 t/h (kg/h)
Digital Input 1 -Belt Stop
-Reset Mass Integrator
-Batch Mode
Belt Stop
Digital Input 2 -External Tare
-Print Start
-External Product 3 + 4
-Start/Stop & Print.
External Tare
Relay 3 -Tare Measurement
-Batch Ready
-Min/Max
Tare Measurement
Min/Max 0 - 9999.9 0,0 t/h
Hysteresis 0 - 999.9 0,0 t/h
Batch Weight 0 - 99999.9 0 t
External Mass
Counter
Tons per Pulse
Off/0.01/0.1/1/10t
1
Print Out Data on
Printer
-no
-Print Shift
-Print Minutes
no
Begin Shift 00:00 07:00h
Shifts per Day 0 - 99 3
Hours per Shift 0 - 99 8
Print out
per Minutes
0 - 999 1 min

Table of Contents