Section 13 Appendix
151
13.7 Configuration List
Measuring Point Date
Isotope Activity
Source: No. Detector
Transport System HV
Product
Function Range Default Values Customer Set Up
General Data
Password 0 - 999999
Date YY.MM.DD Current Datum
Time HH.MM. Current Zeit
Model/Version LB 442 Vers Current Soft. Vers
Detector-Software Ver. 2.X Current Soft. Vers
Language -Deutsch
-English/
-Francais
-Espanol
English
Operating Mode
Config Instrument -Const Belt Speed.
-With Moisture Comp.
-With Tacho
Const. Belt Speed.
Tacho Input -Pulse Input
-Current Input
Pulse Input
Tacho Pulse/Rev. -500 / -2500 / -5000 500
Drive for
Tachometer
-Wheel
-Drive Shaft
Laufrad
Forward Feed per
Revolution
999999 mm 0mm/Umdr.
Unit Selection [t], [kg], [kg/m] t
Error Mode
in Error Case
-Stop Measurement
-Continue Measurement
Stop Measurement
Current Out
in Error Case
-Hold
-Value
Hold
Loading at Stop -Hold last Value
-0/4 mA
Hold
Interfaces
RS 232 -PC
-Printer
PC
RS 485 -Printer
-Slave
-PC
Printer
PC Access Control -Read Only Data
-Change of Data
Read Only Data
Number of
Detectors
1 - 9 1
Slave1 Address 0 - 99 1