5.2 Getting Started
42
- Enable/disable Low load suppression. When enabled, enter low
load in tons.
- Select if Mass integrator is to be cleared after each run (=yes
or if the count should continue (=no).
Return to the menu group with <done>.
2.2 Press <sk2> to select the I/O Config menu and then press
<more> to scroll through the parameters:
- Select Product
- Select Current output 0 or 4 (26a/26c)
- Define Current output limits 0/4 and 20 mA for load
- Define Current Output Error: Hold last measured value or enter
mA value
- Define digital input 1: Belt stop or Erase mass integrator or
batch mode
- Define digital input 2: External tare or Print start, Product 3+4
or Start / Stop and print
- Define Relay 3: Tare measurement or Batch Ready or
Min/Max.
- For Batch Ready enter desired batch weight.
- For Min/Max enter threshold value and hysteresis.
- For Mass counter select tons per pulse
- Data printout: Select none or Minute prints or Shifts. For shift
printout, enter the respective parameters.
- Return to the menu group with <done>.