EasyManua.ls Logo

BMS alpha CR - Page 58

Default Icon
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Layout and function
4.7
Menus
58
No.
Meaning
5
Load control display
− Grey: The motor is switched off.
− Yellow: While the motor is starting.
− Green: While the motor is running.
6
Mixing unit control display
− Grey: The mixing unit is switched off.
− Green: The mixing unit is switched on.
7
Delivery control display
When the mixing time is switched on, the preset time is displayed
as a numerical value in seconds
− Grey: The automatic delivery machine is switched off.
− Flashing yellow: The mixing time is running out.
− Yellow: When delivery is activated, the control indicator lights
up yellow until 2 bar minimum pressure is reached.
− Green: When delivery is activated, the control indicator lights
up green after the minimum pressure is reached.
8
Power Mode
− Standard operation: The OFF key is highlighted in grey.
− Power mode: The key ON is highlighted in blue. The power
mode is activated
9
Fuel gauge
Shows the fill level in the tank in %.
10
Battery voltage
The battery voltage is displayed in V (Volt) as a numerical value
− Green: The current battery voltage is OK
− Yellow/red: The current battery voltage is too low.
11
Coolant temperature
Shows the coolant temperature in °C.

Table of Contents