4
Layout and function
4.7
Menus
58
No.
Meaning
5
Load control display
Grey: The motor is switched off.
Yellow: While the motor is starting.
Green: While the motor is running.
6
Mixing unit control display
Grey: The mixing unit is switched off.
Green: The mixing unit is switched on.
7
Delivery control display
When the mixing time is switched on, the preset time is displayed
as a numerical value in seconds
Grey: The automatic delivery machine is switched off.
Flashing yellow: The mixing time is running out.
Yellow: When delivery is activated, the control indicator lights
up yellow until 2 bar minimum pressure is reached.
Green: When delivery is activated, the control indicator lights
up green after the minimum pressure is reached.
8
Power Mode
Standard operation: The OFF key is highlighted in grey.
Power mode: The key ON is highlighted in blue. The power
mode is activated
9
Fuel gauge
Shows the fill level in the tank in %.
10
Battery voltage
The battery voltage is displayed in V (Volt) as a numerical value
Green: The current battery voltage is OK
Yellow/red: The current battery voltage is too low.
11
Coolant temperature
Shows the coolant temperature in °C.