Storage
11
Preserving the machine
11.4
167
11.4 Preserving the machine
Incorrect or negligent disposal can cause considerable environmental
pollution.
Lubricants, oils and other waste produced when using the machine
must be disposed of in a professional and environmentally friendly
manner.
Disposal must take place in accordance with the applicable national
rules and regulations.
In case of doubt, consult the manufacturer or obtain information on the
environmentally responsible disposal from the local authorities or disposal
specialists.
1. Store the machine in a dry, well-ventilated location.
2. Let the motor warm up and then switch it off.
3. Clean the oil exhaust filter if necessary.
4. Fill up with anti-corrosion oil instead of the normal motor oil.
5. Drain the fuel from the tank.
6. Fill the tank with a mixture of 90% diesel fuel (possibly winter diesel)
and 10 % anti-corrosion oil.
7. Let the motor run for approx. 10 minutes.
8. Switch off the motor.
9. Turn the motor several times by hand to preserve the cylinders and
combustion chambers.
10. Remove the V-belts and store them packaged.
11. Spray the grooves of the V-belt pulleys with anti-corrosion agent.
12. Close the intake and exhaust openings.