Installation
EN
136 bora.com
9 Installation
u
Observe all safety and warning information
(see"2Safety").
u
Follow the enclosed manufacturer’s information.
9.1
General installation
instructions
The power supply cable must be provided by the
customer.
The appliance must not be installed above
cooling devices, dishwashers, stoves, ovens,
washing machines or dryers.
The contact surface of the worktops and wall
sealing strips must be made of a heat-resistant
material (up to approx. 100°C).
Worktop cut-outs must be moisture-sealed
using suitable means and, where necessary,
fitted with a thermal insulator.
The integrated cooktop extractor must not be
used with other cooktops.
General installation instructions for cooktops
u
Make sure that the area below the cooktop has a
sufficient air supply.
To ensure that the cooktops perform optimally
at all times, there must be sufficient ventilation
beneath the cooktops.
The performance of the cooktops is affected or
the cooktops overheat if the warm air beneath
the cooktops cannot escape.
In the event of overheating, the cooktop power
is reduced or the appliance is switched off
completely.
If cable protection (false floor) is planned
beneath the appliance, this must be fitted so it
does not obstruct ventilation.
9.1.1
Simultaneous operation of
the cooktop extractor in the
exhaust air mode and a
fireplace dependent upon the
air supply in the room
National and regional laws and regulations must
be observed with regard to the exhaust duct
design.
A sufficient air supply must be ensured.
Fireplaces that depend on the air in the room (e.g. gas,
oil, wood or coal-fired heaters, continuous-flow water
heaters, instantaneous water heaters) draw in air from
the room in which they are installed and release the
exhaust fumes into the outside air via an exhaust
system (e.g. chimney).
If the cooktop extractor is used in exhaust air mode, it
draws in air from the room in which it is installed as well
as from neighbouring rooms. Without sufficient air,
there will be a drop in air pressure. Toxic gases could be
drawn out of the chimney or extraction ducting and
back into the room.
Fig.9.1
Exhaust air installation – not permitted

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the bora X Pure and is the answer not in the manual?

bora X Pure Specifications

General IconGeneral
Product namebora X Pure
TypeInduction
Integrated extractorYes
Power levels9
Boost FunctionYes
Child LockYes
TimerYes
Residual Heat IndicatorYes
ColorBlack
Product typeCooktop
Control typeTouch
Frequency50 Hz
Material surfaceGlass ceramic
Supply voltage230 V
Air recirculationOptional

Related product manuals