Safety
EN
bora.com 95
PLEASE NOTE
Appliance damage caused by incorrect installation clearances
Failure to adhere to installation clearances can lead to damage to the appliance
and kitchen units, as well as restricted functions.
u
During installation maintain the minimum clearance stated in the Installation
chapter.
2.4.1
Safety instructions – cooktop extractor installation
ö
DANGER
Risk of smoke inhalation
When the cooktop extractor is used in exhaust air mode, it draws in air from
the room it is installed in and from neighbouring rooms. Without sufficient air,
there will be a drop in air pressure. When used at the same time as a fireplace
that is dependent on the air in the room, noxious gases can be sucked into the
living areas from the chimney or outlet shaft.
u
Make sure that there is always a sufficient air supply.
u
Only use reliable, tried-and-tested switching devices, (e.g. window contact
switch, low pressure warning device) and have them approved by a qualified
expert (certified chimney sweep).
ö
WARNING
Risk of injury due to turning fan wheel
There is a risk of injury while the fan is turning.
u
Only install the device with the power disconnected.
u
Connect both sides of the fan to the duct system before commissioning.