1 | Motor mower Brielmaier Brielmaier Motormäher GmbH
16 BA Motor mower S250 (Version 2021/09)
Intermediate plate for the
catch tray offset
1
2
When using spiked rollers with a large diameter, the quick-release coupling
(1) on the attachment must be moved up. When using an extended
mowing unit frame, the quick-release coupling on the attachment must be
moved down. An intermediate plate (2), which is available as an option, is
required for both mounting methods.
Proportional control valves
The standard proportional pressure control valve (PCV) is the right fitting
for most applications.
The proportional pressure control valve (PCV) should only be exchanged for
the proportional flow control valve (FCV) after consulting the
manufacturer/specialist dealer if:
the speed should be adjustable on the attachment.
the oil volume of the motor mower (approx. 32 litres/min at 3600 rpm)
is too large for the attachment.
Both proportional control valves allow a soft start of the attachment.
NOTE
We do not recommend a proportional flow valve for attachments
designed for other oil flow rates. Instead, we recommend replacing the
oil engine in the attachment.

Table of Contents