Confidential
9-10
Error Code
(Hex)
Symptom Probable Cause Solution
Black markings on the
white-level reference
film inside the scanner
top cover.
Clean the white-level
reference film.
CCD defective Replace the CCD unit.
BE Scan starting edge detection
error.
Main PCB defective Replace the main PCB.
BF Duplex scanning cannot be
implemented due to too long
document.
- The document is too
long.
- ADF front sensor 2
defective
Replace the ADF front
sensor 2.
C1-CF Not used.
D0-DF Modem error. Main PCB defective Replace the main PCB.
E0-E3 Not used.
E4 Out of recording paper.
(Not used.)
E5 Not used.
E6 Write error in EEPROM. Main PCB defective Replace the main PCB.
E7 Not used.
CCD defective Replace the scanner cover
(scanner unit).
E8
Data scanning error during
transmission.
Main PCB defective Replace the main PCB.
E9 Not used.
Document front sensor
actuator caught on the
surrounding parts
Correct the surrounding
parts on which the
actuator caught.
Sensor PCB defective Replace the sensor PCB.
EA Document removed at phase
B.
Main PCB defective Replace the main PCB.
EB-ED Not used.
EE-F2 Not used.
F3, F5
Internal software error.
(Not used.)
F4 Not used.
F6 PC interface error. (Not used.)
F7-FE Not used.
FF Memory management error.
(Not used.)