2-96
Confidential
■ Error code E8
The scanned data fails to be recorded in the buffer RAM.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
■ Error code E9
Main PCB error.
■ Error code EA
Communication data error upon scanning.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable E9
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
---
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.