9.75 MP Sector Solenoid
(1) Disconnect the wiring of the MP sector solenoid.
(2) Remove the Taptite bind B M3x8 screw. Remove the MP sector solenoid and Solenoid
spring MP from the PF ASSY.
Fig. 3-307
Fig. 3-308
Harness routing: Refer to PF ASSY”
Assembling Note:
When assembling the MP sector solenoid, be sure to assemble it as shown in the figure
below.
Taptite bind B M3x8
PF ASSY
MP sector solenoid
Solenoid spring MP
MP sector solenoid
PF ASSY
MP sector lever