2-37
Confidential
■ Error code 1B (C)
Error code 1C (M)
Error code 1D (Y)
Drum error. (An drum error occurred after the counter value exceeded the value more than
twice as long as the life of the drum.) (Printing is not available until the drum unit is replaced.)
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
■ Error code 1E
The drum unit will reach the end of life soon.
<User Check>
- Prepare a new drum unit.
■ Error code 1F
More than the specified number of the option trays is installed.
This error does not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Drum Stop
We cannot guarantee the print quality. Replace the Drum Unit. Refer to the
User’s Guide for instructions.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Replace Parts
Drum
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Too Many Trays.
Maximum number of optional tray is one. Remove additional trays.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.