2-41
Confidential
■ Error code 2A
Develop release motor error.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
■ Error code 2B
Blower error.
<User Check>
- Turn OFF the power switch, and turn it ON again after a while.
Print Unable 2A
Turn the power off and then back on again.
Step Cause Remedy
1 Harness connection failure of
develop release motor
Check the harness connection of the
develop release motor and
reconnect it.
2 Develop release motor failure Replace the develop release motor.
3 Engine PCB failure Replace the engine PCB ASSY.
4 Low-voltage power supply PCB
failure
Replace the low-voltage power supply
PCB ASSY.
5 Main PCB failure Replace the main PCB ASSY.
Print Unable 2B
Turn the power off and then back on again.
Step Cause Remedy
1 Harness connection failure of
blower
Check the harness connection of the
blower and reconnect it.
2 Blower failure Replace the blower.
3 High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.
4 Main PCB failure Replace the main PCB ASSY.