5 4 Repair Manual RRE140/160/180/200/250 © BT
Installation
Initial operation
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
Cold store cabin
When the cabin door is not shut, the truck is braked by the motor until it
stops.
An option is available that allows the truck to be driven (2.5 km/h) with
the door open; this may be deselected.
.
5.2.3 Parameters for optional equipment
Height measurement (option)
Parameter 1009 sets the type of height measurement the truck is to
have.
Can be combined with the LID (Load Indication Display) (option) and
then height information is displayed on the LID.
Travel speed limitation, height-dependent
Requires the full height measurement option. Limits travel speed
when the forks are above a given predetermined height.
Travel speed limitation, reach movement dependent
Limits travel speed when the mast is extended beyond a given
predetermined millimetre limit.
Door open action (cold store cabin) Parameter no. 116
Disable operation (driving) 0
Speed limited to 2.5 km/h 1
Height measurement, type Parameter no.
344 1009
Base version, only position sensors 0
Full measurement (option) 1 1
Speed reduction for a selectable
height
Parameter no.
209 210
Height limit for speed reduction mm
Speed limitation above selected height km/h
Speed reduction for a selectable
reach movement length
Parameter no.
211 212
Reach movement length for speed limita-
tion
mm
Speed limitation beyond a selected limit km/h

Table of Contents