Functions and parameters
Functions
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT  Repair Manual  RRE140/160/180/200/250  4 –   53
Auxiliary/Extra functions (option)
All the hydraulic functions in this section, as listed below, are connected 
to the hydraulic main valve's extra outputs: AUX (auxiliary).
The functions cannot be used at the same time as certain other hydrau-
lic functions.
All extra functionscan be calibrated by means of a number of parame-
ters.
Fork tilt
Fork tilt uses the first auxiliary output.
If an angle sensor is connected, a LED icon comes on in the LID 
(option) when the forks are in their initial position, in other words, when 
the angle is zero degrees.
Sideshift
Sideshift uses the second auxiliary output.
If a sensor is connected to measure the mid position, a LED icon in the 
LID (option) comes on once the mid position is reached.
Forkspread and telescopic forks
The telescopic forks use the third auxiliary output and forkspread uses 
the fourth auxiliary output.