4 68 Repair Manual RRE140/160/180/200/250 © BT
Functions and parameters
Parameters
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
4.13 Parameters
4.13.1 General
The trucks control system can store a number of different parameters.
These are used to configure the truck according to the task to be per
-
formed. The parameters are split into two groups:
Operator parameters – The operator parameters (range 1 – 100) are
used to adapt the trucks response to a specific operator or task. Up
to ten operator parameters can be stored.
Service parameters – The service parameters (range 101 – 1000)
are used to adapt the trucks performance/response; they cover all
other parameters not covered by the operator parameters.
Factory parameters – (range 1001 – 1250). Truck-specific parame-
ters.
Calibration parameters – (range 1251 – 1500) are used to calibrate
valves, weight indication, etc.
Operator parameters are displayed and changed only for a selected
operator, but if a CAN service key is connected, the parameters for all
operators can be displayed and changed. Operator parameters can be
changed by the operator if the truck's program is set up for this.
The service parameters can be changed once a suitable CAN service
key or PDA/PC has been connected to the truck.
Factory parameters can ONLY be changed once a specially configured
PDA/PC has been connected to the truck.