Loading...
4 70 Repair Manual RRE140/160/180/200/250 © BT
Functions and parameters
Parameters
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
Service parameters, overview
No. Min. Max. In-
cre-
ment
De-
fault
Unit Description
General parameters
101 0 5000 100 0 h Service interval. Time till next service in B-
time.
0 = deactivated
104 0 120 1 20 min Log-off timer
0 = 4 hours
107 1 20 1 12 Battery size
108 0 20 5 5 % Limit for start of reduction in performance as
% of BDI
109 0 2 1 0 Delete data on login
0 = Do not clear data
1 = Clear histogram log
2 = Clear crash log
110 0 100 1 0 Impact sensor X
0 = deactivated
1–100 sensitivity setting
111 0 100 1 0 Impact sensor Y
0 = deactivated
1–100 sensitivity setting
112 0 1 1 0 Impact sensor, action after collision
0 = Login with special PIN code to reset sen-
sor
1 = Restart the truck to reset
113 50 1000 1 246 Shunt resistance for BDI (resistance for the
shunt resistance in question)
114 0 7 1 0 Travel alarm 1 (X) setting
115 0 3 1 0 Travel alarm 2 (Y) setting
116 0 1 1 0 Door open action (cold store cabin)
0 = Disable operation
1 = Speed limited to 2.5 km/h
Driving parameters
201 50 100 10 100 % Reversing speed
202 30 100 10 100 % Creep speed
203 30 100 10 100 % Half speed
204 30 100 10 100 % Safety speed
205 0 100 10 100 % Speed limitation 1
206 0 100 10 100 % Speed limitation 2
207 0 100 10 100 % Speed limitation 3