Functions and parameters
Height preselector, description of function
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 55
4.9.4 Height preselector levels
The height preselector levels are organised in aisles with levels –
heights – defined for each aisle. A maximum of 200 heights can be
stored and service parameter 511, Aisle configuration, gives the
number of heights/aisle.
The applicable parameter values are listed below:
In the CID and LID displays, the aisles and levels are written in the for-
mat "aa:nnn", where "aa" is the aisle and "nnn" is the level for the row.
Depending on the setting of the parameter for the number of aisles,
there can be one or two digits for the aisle and one to three digits for the
level.
4.9.5 Level selection
The height preselector levels are selected using the CID keypad.
To select a level, press the digits on the keypad, leaving no more than
0.5 of a second between each one that you press. Once the final digit
has been entered, the level selected will appear approximately 0.5 of a
second later.
When a aisle is to be selected, the digits are entered in the same way
as for a level, but the sequence is ended by pressing the green button
(I).
Levels can be selected irrespective of the aisle. If a new aisle is select-
ed, any previous levels selected are reset
Value Aisles Heights/aisle
1 1 200
2 2 100
3 4 50
4 5 40
5 8 25
6 10 20
7 20 10
8 40 5
Event Display
Press the number 1 --:--
Press the number 4 (within 0.5 s) --:--
Press the green button (I) (within 0.5
s)
14:--
Press the number 9 14:--
Wait 0.5 s until level 9 is selected 14:9