Functions and parameters
Operator compartment
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 21
CID disable indications in the display area
Sym-
bol
Description Sym-
bol
Description
Height limit.
The lift height limit has
been reached.
The travel speed has
been reduced via the
input to the MCU.
The reduction is param-
eter-based.
Function reactivation.
Reactivation of the
requested function is
required to be able to
use the truck.
Seat switch.
The truck cannot be
used as the seat switch
has not been activated.
Safety pedal.
The truck cannot be
operated as the pres
-
ence check has not
been activated.
Temperature.
The temperature in the
transistor regulator for
the drive or hydraulics
is over 85
°C.
ESO (Emergency
Switch Off)
The emergency stop
button has been
depressed.
Service.
Time until the next serv-
ice.
The service interval is
set with parameter 101.
Looking for reference
sensor.
None of the reference
sensors read.
Looking for lower refer-
ence sensor.
Sensor [B58] for lower
lift reference not read.
Looking for upper refer-
ence sensor.
Sensor [B46]/[B57] for
upper lift reference not
read.
Main lift started.
The indication is dis-
played when attempt-
ing to drive at >4 km/h
with the main lift mast
raised.
Travel speed is limited
to 4
km/h.
Cold store cabin – Door
open.
Driving disabled or lim-
ited to 2.5 km/h.
Controlled by parameter
116.

Table of Contents