State 3 – Voltages to MCU
State 3 displays the voltage to the MCU from 10 analogue controls and
sensors on the truck. The value is displayed in volts to 2 decimal plac
-
es.
No. MCU signal
1
A1 X130:2
2
A2 X130:16 Fork tilt indicator
3
A3 X130:30 Hydraulic pressure, main lift
4
A4 X130:3 Hydraulic pressure, free lift
5
A5 X130:17 Accelerator
6
A6 X130:31 Safety pedal
7
A7 X130:4 Brake pedal 1
8
A8 X130:18 Brake pedal 2
9
A9 X130:32 Power consumption
10
A10 X130:5 Battery voltage +